Table 2 Epidemiological parameters considered in the analytic model

From: Cost-effectiveness of diagnostic for malaria in Extra-Amazon Region, Brazil

Parameter

Base-case value

Variation values

Information sources

Prevalence of malaria among febrile patients seeking diagnosis

0.467

0.560 e 0.373

Base-case: Ministry of Health

   

Variation: 20% above and below the base-case.

Proportion of malaria cases due to Plasmodium vivax

0.713

0.856-0.570

Base-case: Ministry of Health

   

Variation: 20% above and below the base-case.

Proportion of malaria cases due to Plasmodium falciparum

0.287

0.344-0.230

Base-case: Ministry of Health

   

Variation: 20% above and below the base-case.

Sensitivity of microscopy for Plasmodium vivax

0.950

0.717

Base-case: Ohrt e et al., 2002 - Variation: Andrade e et al., 2010.

Specificity of microscopy for Plasmodium vivax

1.000

0.950

Base-case: Haghdoost et al., 2006; Variation: Haghdoost et al., 2006.

Sensitivity of microscopy for Plasmodium falciparum

0.976

0.757

Base-case: Alam et al., 2011; Variation: Andrade et al., 2010.

Specificity of microscopy for Plasmodium falciparum

1.000

0.932

Base-case: Andrade et al., 2010; Variation: Alam e et al., 2011;

Sensitivity of CareStartâ„¢ for Plasmodium vivax

0.953

0.711-1.000

Base-case: Mekonnen et al., 2010; Variation: Upper value: Sharew e et al., 2009. Lower value: Ashley e et al., 2009.

Specificity of CareStartâ„¢ for Plasmodium vivax

1.000

0.919

Base-case: Mekonnen e et al., 2010; Variation: Ratsimbasoa e et al., 2007.

Sensitivity of CareStartâ„¢ for Plasmodium falciparum

0.964

0.854-1.000

Base-case: Mekonnen et al., 2010; Variation: Upper value: Sharew e et al., 2009. Lower value: Ashley e et al., 2009.

Specificity of CareStartâ„¢ for Plasmodium falciparum

1.000

0.881

Base-case: Mekonnen et al., 2010; Variation: Ratsimbasoa e et al., 2007.

Sensitivity of First Response Malaria Comboâ„¢ for Plasmodium vivax

0.842

0.721-0.925

Base-case: Singh et al., 2010; Variation: Singh et al., 2010

Specificity of First Response Malaria Comboâ„¢ for Plasmodium vivax

0.940

0.900 – 0.982

Base-case: Bharti e et al., 2008; Variation: Upper value: Singh et al., 2010. Lower value: Bharti et al., 2008.

Sensitivity of First Response Malaria Comboâ„¢ for Plasmodium falciparum

0.960

0.880-0.990

Base-case: Bharti e et al., 2008; Variation: Bharti e et al., 2008.

Specificity of First Response Malaria Comboâ„¢ for Plasmodium falciparum

0.950

0.756-0.970

Base-case: Bharti et al.,2008; Variation: Upper value: Bharti et al., 2008. Lower value: Singh et al., 2010.

Sensitivity of Parascreenâ„¢ for Plasmodium vivax

0.772

0.642-0.873

Base-case: Singh e et al., 2010; Variation: Singh e et al., 2010.

Specificity of Parascreenâ„¢ for Plasmodium vivax

0.981

0.959-0.993

Base-case: Singh et al., 2010; Variation: Singh et al., 2010.

Sensitivity of Parascreenâ„¢ for Plasmodium falciparum

0.940

0.885-0.974

Base-case: Singh et al., 2010; Variation: Singh et al., 2010.

Specificity of Parascreenâ„¢ for Plasmodium falciparum

0.720

0.658-0.776

Base-case: Singh et al., 2010; Variation: Singh et al., 2010.

Sensitivity of BinaxNOWâ„¢ for Plasmodium vivax

0.873

0.729-0.930

Base-case: Wongsrichanalai et al., 2003; Variation: Upper value: Wongsrichanalai et al., 2003. Lower value: Pabón et al., 2007.

Specificity of BinaxNOWâ„¢ for Plasmodium vivax

0.977

0.995-1.00

Base-case: Wongsrichanalai et al., 2003; Variation: Pabón e et al., 2007.

Sensitivity of BinaxNOWâ„¢ for Plasmodium falciparum

1.000

0.520-0.960

Base-case: Wongsrichanalai et al., 2003; Variation: Upper value: Farcas et al., 2003. Lower value: Pabón et al., 2007.

Specificity of BinaxNOWâ„¢ for Plasmodium falciparum

0.962

0.920-0.980

Base-case: Wongsrichanalai et al., 2003; Variation: Wongsrichanalai et al., 2003.

Sensitivity of SD Bioline FK60 (PF/Pan)â„¢ for Plasmodium vivax

0.710

0.636(0.424-0.815)

Base-case: Vas Dev, 2004. Variation: Ratsimbasoa, 2008 (1)

Specificity of SD Bioline FK60 (PF/Pan)â„¢ for Plasmodium vivax

1.000

0.989(0.946-0.999)

Base-case: Vas Dev, 2004. Variation: Ratsimbasoa, 2008

Sensitivity of SD Bioline FK60 (PF/Pan)â„¢ for Plasmodium falciparum

1.000

0.929 (0.889-0.971)

Base-case: Vas Dev, 2004. Variation: Ratsimbasoa, 2008

Specificity of SD Bioline FK60 (PF/Pan)â„¢ for Plasmodium falciparum

1.000

0.989 (0.946-0.999)

Caso-base: Vas Dev, 2004. Variação: Ratsimbasoa, 2008

  1. Extra-Amazon Region, Brazil, 2010.
  2. Note: (1) Exception: The article by Ratsimbasoa (2008) used a combination of PCR and thick smear as the gold standard.