Skip to main content

Table 3 Performance of test kit on interfering substances

From: Development and performance evaluation of a novel immunofluorescence chromatographic assay for histidine-rich protein 2 of Plasmodium falciparum

Interfering substance

Conc.

Cases

Negative reference samples

Positive reference samples

Criterion

Results

Criterion

Results

Bilirubin

2 g/L

20

10/10−/−

10/10−/−

10/10+/+

10/10+/+

Triglycerides

30 g/L

20

10/10−/−

10/10−/−

10/10+/+

10/10+/+

Cholesterol

15 g/L

20

10/10−/−

10/10−/−

10/10+/+

10/10+/+

Rheumatoid factor

320 IU/ml

20

10/10−/−

10/10−/−

10/10+/+

10/10+/+

  1. 10/10−/− indicates that all negative samples were tested negative for ten repeated times, and 10/10+/+ indicates that all positive samples were tested positive for ten repeated times