Skip to main content

Table 3 Diagnostic accuracy of PfHRP2 based rapid diagnostic test performed by study nurses at health facilities (HF-PfHRP2) and PfHRP2 based rapid diagnostic test performed at the central microbiology laboratory (Lab PfHRP2) by trained technicians compared using expert microscopy as gold standard

From: Implementation of a malaria rapid diagnostic test in a rural setting of Nanoro, Burkina Faso: from expectation to reality

Diagnostic performance characteristic

HF-PfHRP2

Lab-PfHRP2

% (n/N)

95% CI

% (n/N)

95% CI

Sensitivity

97.5 (238/244)

94.7–99.1

98.4 (240/244)

95.9–99.6

Specificity

52.8 (86/163)

44.8–60.6

74.2 (121/163)

66.8–80.8

Positive predictive value

75.6 (238/315)

72.4–78.5

85.1 (240/282)

81.5–88.1

Negative predictive value

93.5 (86/92)

86.5–97.0

96.8 (121/125)

91.9–98.8