Table 2 Performance of the rapid diagnostic test used in the study

From: Prevalence of malaria among febrile patients and assessment of efficacy of artemether-lumefantrine and artesunate-amodiaquine for uncomplicated malaria in Dolisie, Republic of the Congo

Reference method

RDT positive

RDT negative

Total

Microscopy positive

263

3

266

Microscopy negative

60

668

728

Total

323

671

994

  1. The performance of the Standard Diagnostic Malaria AG Pf HRP2/pLDH rapid diagnostic test (RDT) compared to microscopy (reference method) was as follows: sensitivity, 98.9%; specificity, 91.8%; positive predictive value, 81.4%; and negative predictive value, 99.6%. The kappa coefficient was 0.86, which corresponds to an “almost perfect agreement” between the two diagnostic methods, according to the classification proposed by Landis and Koch [29]