Skip to main content

Table 4 Strength measures of commercial nets

From: Strength of bed nets as function of denier, knitting pattern, texturizing and polymer

Sample

Weight/m2 (g)

Bursting Strength (kPa at mm)

Tension Strength Grab Hook Length (Newton)

Tension Strength Grab Hook Width (N)

Tension Strength Two Grabs Length (N)

Tension Strength Two Grabs Width (N)

Permanet 2 100 D

42,6

400 at 10 mm cd

28,6d

23,7c

  

Permanet 2 75 D

32,5

388 at 8,7 mm d

28,1d

18,0cd

  

Permanet 2 75 D

30,1

328 at 10 mm e

14,4d

15,8d

120

110

Permanet 3 Upper part

32,0

285 at 8,8 mm ef

15,5d

19,6cd

  

Permanet 3 Lower Part

41,9

324 at 8,3 mm f

18,7d

19,0cd

  

Interceptor 75 D

35,0

247 at 15 mm f

16,8d

14,3d

110

83

Duranet 255 D

47,7

616 at 12 mm a

88,9bc

53,8a

  

Netprotect 100 D

34,6

385 at 14 mm bcd

66,9c

40,3b

  

Netprotect 118 D

39,2

427 at 15 mm cd

88,9ab

47,6b

230

150

Olyset 205 D

54,2

468 at 14 mm b

99,4a

47,6b

290

250

Permanet 3 roof 145 D

43,6

445 at 12 mm bc

53,9c

42,0b

  
  1. The table shows average values of min 5 determinations per net or net part (data from report 8202/2009 and 727/2010 - CITEVE). Values with same letter are not significant different (Tukey test).