Table 2 Sensitivity and specificity of SDFK90 for the detection of Plasmodium falciparum

From: Evaluation of the malaria rapid diagnostic test SDFK90: detection of both PfHRP2 and Pf-pLDH

Microscopy corrected by PCR

Number

Identified as P. falciparum by SDFK90

% Sensitivity (95% CI)

% Specificity (95% CI)

All P. falciparum samples

336

331

98.5 (96.6-99.5)

 

Pure gametocytaemia

18

16

88.9 (65.3-98.6)

 

Asexual parasite density 1-100/μl

36

35

97.2 (85.5-99.9)

 

Asexual parasite density 101-200/μl

19

19

100 (82.4-100)

 

Asexual parasite density 201-1,000/μl

44

43

97.7 (88.0-99.9)

 

Asexual parasite density >1,000/μl

219

218

99.5 (97.5-100)

 

Asexual parasite density >100/μl

282

280

99.3 (97.2-99.9)

 

Excluding pure gametocytaemia

318

315

99.1 (97.3-99.8)

 

All other species and no parasites detected

255

3

 

98.8 (96.6-99.8)

No parasites detected

96

0

  

P. vivax

72

3

  

P. ovale

71

0

  

P. malariae

16

0