Table 3 The differences in parasite detection amongst the two methods, using PCR as the gold standard

From: Plasmodium falciparum diagnostic tools in HIV-positive under-5-year-olds in two ART clinics in Ghana: are there missed infections?

 

Variable

HIV+

Minimum parasite density/µl

HIV−

Minimum parasite density/µl

RDTa

True positive

5

19,608

44

53,846

False positive

0

0

Total test positive

5

19,608

44

53,846

False negative

1

17,087

12

11,107

True negative

144

195

Total test negative

145

 

207

 

Microscopy

True positive

6

19,201

50

53,121

False positive

0

0

Total test positive

6

19,201

50

53,121

False negative

0

6

21

True negative

144

195

Total test negative

144

 

201

 

PCR

Gold standard

6

19,608

56

53,846

  1. aParasite count for RDT was done with real time PCR