Skip to main content

Detection of P. malariae using a new rapid isothermal amplification lateral flow assay

Abstract

Background

While Plasmodium falciparum and Plasmodium vivax cause the majority of malaria cases and deaths, infection by Plasmodium malariae and other Plasmodium species also causes morbidity and mortality. Current understanding of these infections is limited in part by existing point-of-care diagnostics that fail to differentiate them and have poor sensitivity for low-density infections. Accurate diagnosis currently requires molecular assays performed in well-resourced laboratories. This report describes the development of a P. malariae diagnostic assay that uses rapid, isothermal recombinase polymerase amplification (RPA) and lateral-flow-strip detection.

Methods

Multiple combinations of custom RPA primers and probes were designed using publicly available P. malariae genomic sequences, and by modifying published primer sets. Based on manufacturer RPA reaction conditions (TwistDx nfo kit), an isothermal assay was optimized targeting the multicopy P. malariae 18S rRNA gene with 39 °C incubation and 30-min run time. RPA product was visualized using lateral strips (FAM-labeled, biotinylated amplicon detected by a sandwich immunoassay, visualized using gold nanoparticles). Analytical sensitivity was evaluated using 18S rRNA plasmid DNA, and clinical sensitivity determined using qPCR-confirmed samples collected from Tanzania, Ethiopia, and the Democratic Republic of the Congo.

Results

Using 18S rRNA plasmid DNA, the assay demonstrates a detection limit of 10 copies/µL (~ 1.7 genome equivalents) and 100% analytical specificity. Testing in field samples showed 95% clinical sensitivity and 88% specificity compared to qPCR. Total assay time was less than 40 min.

Conclusion

Combined with simplified DNA extraction methods, the assay has potential for future field-deployable, point-of-care use to detect P. malariae infection, which remains largely undiagnosed but a neglected cause of chronic malaria. The assay provides a rapid, simple readout on a lateral flow strip without the need for expensive laboratory equipment.

Background

Intensive malaria control efforts have yielded progress toward malaria elimination in multiple endemic countries [1]. In some settings, as the burden of Plasmodium falciparum and Plasmodium vivax malaria declines, less common species such as Plasmodium malariae and Plasmodium ovale have increased in prevalence as well as public health relevance [2,3,4]. Malaria elimination requires rapid detection and treatment of all Plasmodium species. However, existing rapid methods are not species-specific and have poor sensitivity for these less common species [5]. Though P. malariae is known to cause chronic parasitaemia, sometimes lasting years, and causing chronic anaemia and splenomegaly [6], its treatment is straightforward. Thus, its detection and treatment can reduce chronic carriage and contribute to malaria elimination efforts. This study reports a new P. malariae-specific diagnostic assay that uses rapid, isothermal recombinase polymerase amplification (RPA) and lateral flow strip detection and has potential for further development into a point-of-care tool.

Methods

Primer and probe design

Primers and probes were designed according to manufacturer-suggested best practices [TwistDX(TwistAmpTM nfo), Cambridge, UK]. Primers were designed to meet the following parameters: 30–36 nucleotide (nt) length, 40–50% GC content, 50–100 °C melting temperature, < 5nt mononucleotide repeat length, and 80-500nt amplicon length. Publicly available Pm 18S ribosomal RNA gene sequences from PlasmoDB and NCBI databases were used to design primers using Primer3Plus v3.2. Primers from published literature were also modified and used to guide selection of target regions [7,8,9]. Probes were designed within the target sequence, with 46-52nt length, 20–80% GC content, and 57–80 °C melting temperature.

RPA assay protocol

RPA reactions were performed using a reverse primer biotinylated on the 5′ end and an unlabelled forward primer; a 5′-FAM-labelled probe with an abasic residue and 3′ blocker modification. The blocker prevents extension until cleavage of the abasic site by Endonuclease IV (nfo) enzyme. The biotinylated primer and FAM labelled probe form a duplex of double-stranded RPA amplicons that are detectable by sandwich assay, involving a lateral flow strip test band containing anti-FAM antibodies. Direct visualization by naked eye is possible using streptavidin-gold conjugates that bind biotinylated double stranded amplicon captured by anti-FAM antibodies on the lateral flow strip (Fig. 1).

Fig. 1
figure 1

Plasmodium malariae lateral-flow based RPA assay schematic. (1) Reaction components include unlabelled forward and 5′-biotinylated reverse primers, 5′-FAM labelled probe with an abasic residue and 3′ blocker, endonuclease IV enzyme (nfo), and template DNA. (2) RPA reaction proceeds via primer-recombinase-SSB complex de-looping, nfo cleavage, polymerase extension that results in FAM- and biotin-labelled double-stranded amplicons. Exponential amplification occurs during 20-min isothermal incubation at 39 °C. (3) Lateral flow strips with a band containing anti-FAM antibodies are loaded with RPA product diluted in buffer containing streptavidin-conjugated gold nanoparticles. (4) Detection of labelled RPA product immobilized on the lateral flow strip is performed by visual inspection using the naked eye. Total reaction time is approximately 35 min. Figure made using BioRender

The RPA assay was performed as per manufacturer instructions with slight modifications and using 10 µL reaction volumes (comprising 9 µL of master mix and 1 µL of DNA template). Forty five µL of master mix per five reactions (or proportional equivalent) was prepared, containing 29.5 μL RPA-nfo rehydration buffer, 2.5 μL 280 nM MgOAc, 2.1 μL forward primer (10 μM) and 2.1 μL reverse primer (10 μM), 0.6 μL of probe (10 μM), 1 μL (200 ng/μL) human DNA (for non-clinical samples), and 6.2–7.2 µL molecular-grade water. Reactions were incubated at 39 °C for 30 min with brief intermittent vortexing after 4 min. After amplification, 2 μL of each reaction was immediately diluted with 98 μL of wash buffer in an Eppendorf tube, and a disposable lateral flow strip (Ustar Biotechnologies Ltd, Hangzhou, China REF: D001-03) was dipped into the tube. The result was recorded after 5 min, although results are usually apparent earlier. A test was considered positive when both the test line and control line visualized by the naked eye; and negative only when the control line is visible. When no line appeared, the result was considered invalid. Samples with invalid results were retested.

Assay optimization

Both TwistDX basic and TwistDX nfo kits were used during optimization of reaction conditions before evaluation of assay performance. TwistDX basic products were denatured using heat (60 °C for 10 min) or purified using commercially available DNA purification kit (Qiagen, Germantown, USA) and visualized by 3% agarose gel electrophoresis. The RPA reaction was performed according to manufacturer’s protocol except with temperature ranging from 34–40 °C for 30 min. For non-clinical samples, 18S rRNA plasmid DNA was combined with 200 ng of human DNA to simulate human sample collection.

Assessment of assay performance

To determine analytical sensitivity and specificity of the assay, 18S rRNA plasmid DNA of P. malariae (MRA-179, Lot: 70031271), P. falciparum (MRA-152-G, Lot: 59201399), P. vivax (MRA-178, Lot: 58067149), and P. ovale (MRA-180, Lot: 70043212) obtained from MR4 (BEI Resources, Manassas, USA) was used. To determine limit of detection, P. malariae 18S rRNA plasmid DNA was diluted from 106 to 10–1 copies/μL. Analytical specificity was evaluated using 18S rRNA DNA from other Plasmodium species at high concentration (P. falciparum and P. vivax at 106 copies/µL, P. ovale at 103 copies/µL). Each reaction (RPA and lateral flow detection) was performed with a minimum of four replicates.

Clinical sensitivity and specificity were evaluated using genomic DNA from patients infected with P. malariae, P. falciparum, P. ovale spp., and/or P. vivax collected as part of studies in Tanzania, Democratic Republic of Congo (DRC), and Ethiopia [10,11,12]. Clinical samples were tested using RPA performed in singleton; all sensitivity and specificity estimates were determined using these results. Posthoc, repeat testing was performed for one P. vivax sample. For all studies, participants provided informed consent or parental consent was obtained at the time of enrollment. DNA was extracted from dried blood spot samples using Chelex-100, and evaluated for P. malariae, P. falciparum, P. ovale spp., and P. vivax infection using real-time PCR targeting the 18S rRNA gene as previously described [10].

Results

Selection of primers, probe, and optimized conditions

Fifteen primer pairs were evaluated for the current P. malariae RPA assay (listed in Additional file 1: Table S1). The length of the primers tested ranged between 30 and 41 nt, with melting temperature ranging from 51 to 62.4 °C and GC content ranging from 20 to 41%. The best performing primers and probe during initial testing using TwistDX basic kits were selected for further evaluation and validation using the TwistDx nfo kit: primers AJMP_7: 5′-ATAACATAGTTGTACGTTAAGAATAACCGC-3′ (forward), AJMP_30: 5′- ATATATAATACTTCGATTAGTTGAGTACCT-3′ (reverse), and probe AJMP_42: 5′- GTTGTACGTTAAGAATAACCGCCAAGGCTTTATTTTTTCTGTTAC-3′. Primer and probe modifications are described in Additional file 2: Table S2. The optimized RPA assay reaction consisted of two-steps (Fig. 2): (1) RPA assay in a heat block at 39 °C for 30 min, and (2) lateral flow assay detection with visualization of results after 5 min (35–45-min total reaction time, not including DNA extraction or reagent preparation).

Fig. 2
figure 2

Assay workflow and timeline. Sample collection, DNA extraction (and thawing of DNA and reagents, if necessary) times vary by method. Newer methods enable rapid extraction in ≤ 10 min (e.g., QuickExtract DNA, Biosearch Technologies, Hoddesdon, UK), but at higher cost, whereas conventional Chelex extraction can require up to 24 h at lower cost. Incubation temperature can be varied, though 39 °C was optimal for the assay. Visualization of positive results is often possible in < 2 min but reported at 5 min to standardize assay output. Figure made using BioRender

Analytical sensitivity and specificity

The assay’s analytical sensitivity approached the sensitivity of P. malariae-specific PCR assays [8] and achieved perfect analytical specificity (Fig. 3A, B). When tested against serial dilutions of P. malariae 18S rRNA plasmid DNA, the lower limit of detection was between 10 and 100 copies/µL (~ 1.7–17 genome equivalents/µL, assuming six copies of 18S rRNA per genome [12, 13], with all replicates containing ≥ 10 P. malariae copies/µL detected except for a single replicate. Specificity assessed using high-concentration plasmid DNA for P. falciparum (106 genomes/µL), P. vivax (106), and P. ovale spp. (103) confirmed 100% analytical specificity.

Fig. 3
figure 3

Sensitivity and specificity of the P. malariae RPA-lateral flow (RPA-LF) assay. A Analytical sensitivity and specificity determined using serially diluted 18S rRNA plasmid copies/µL (equivalent to approximately 1700–0.17 genome equivalents/µL). B Example lateral flow read-out by species (Pf, P. falciparum; Pv, P. vivax; Po, P. ovale spp.; Pm, P. malariae; NTC, no-template control). C Clinical sensitivity determined using 21 Tanzania field samples with qPCR-confirmed P. malariae infection with a range of qPCR-determined parasite densities (log10). One low-density case was missed (*). Three cases of Pm + Pf co-infection were included (^); the parasite density indicated for these Pm + Pf cases refers only to Pm. D Clinical specificity determined using Tanzania and Ethiopia field samples with qPCR-confirmed P. falciparum, P. ovale, and P. vivax

Clinical sensitivity and specificity

Clinical sensitivity and specificity assessed using field samples from Tanzania and Ethiopia were excellent, with only a single false-negative and false-positive, respectively (Fig. 3C, D). The assay’s clinical sensitivity compared to qPCR was 95.2%, detecting 20 of 21 P. malariae qPCR-confirmed field samples (17 mono-infected and three mixed P. falciparum and P. malariae co-infection) from Tanzania with a range of parasite densities down to 100 and 10–1 parasites/µL, corresponding to Ct values ranging 22–41. A single false-negative result was observed in P. malariae field sample with parasite density of 0.5 parasites/µL, below the assay’s analytical limits of detection. Clinical specificity was 88% during testing against three P. falciparum, two P. ovale spp., and three P. vivax field samples from Tanzania and Ethiopia. One false-positive result was observed in a P. vivax field sample from Ethiopia, with a faint positive band that was not visualized during repeat posthoc testing.

Discussion

This study describes a new P. malariae RPA-lateral flow assay with strong performance when applied to laboratory and field samples, and potential for development for future use in the field. Species-specific point-of-care assays for neglected Plasmodium species such as P. malariae are not currently available. PCR assays for these species require thermocyclers and materials that are not available in many settings where malaria is endemic. This P. malariae RPA-LF assay provides a simple, sensitive, and specific option to detect P. malariae in laboratories in low-resource settings.

The P. malariae-specific RPA-LF assay achieved limits of detection 10–100 fold better than existing pan-Plasmodium lactate dehydrogenase rapid diagnostic tests, with a lower limit of detection of 1.7–16.7 versus 100–1000 parasites/µL, respectively [14]. The assay had perfect analytical specificity and yielded only a single false-negative during testing against field samples. The false-negative result was observed in a sample with low parasite density below the assay’s limit of detection. While the assay detected several other field samples with lower parasite densities, its performance against low-density samples ≤ 10 parasites/µL is expected to be less robust than higher-density samples, but this is also the case with qPCR. Assay performance was comparable to other laboratory-based molecular methods such as PCR and loop-mediated isothermal amplification (LAMP) for P. falciparum (Table 1). It was also less complex than CRISPR-based assays that incorporate RPA, though with lower sensitivity for P. malariae detection [15, 16]. The assay had excellent specificity, achieving perfect results versus high-concentration plasmid DNA. Its single false-positive during testing of field samples involved a faintly positive test band that was not observed during repeat testing performed as part of post hoc analysis. This suggests that the initial false-positive call was likely a result of contamination during sample processing and RPA-lateral flow testing.

Table 1 Comparison of malaria diagnostic methods (adapted from Mbanefo and Kumar 2020)

RPA provides a rapid method of amplification, reportedly faster than other isothermal amplification methods [17], that can be performed at/near human physiological temperatures. The assay had a total reaction time of less than 40 min and performed best at 39 °C, suggesting opportunities for future use without a heat block (for example, incubation in the axilla or near a simple stove), though these approaches are not yet tested.

Several limitations must be overcome before the current assay is ready for point-of-care use. First, reagent stock outs hampered RPA-lateral flow diagnostic development throughout the COVID-19 pandemic and have not been rectified. Alternatives to TwistDx’s proprietary approaches and kits are now becoming available [18]. Second, the assay requires DNA input and cannot be applied directly to whole-blood samples in its current form. DNA extraction is required prior to performance of the RPA-lateral flow assay and adds time and complexity to sample processing. Advances in simple DNA extraction methods promise rapid turnaround time (< 10 min), but nonetheless add complexity to the workflow. One-pot reactions that eliminate this requirement would simplify assay requirements and improve assay performance. Third, though the assay outperforms pan-Plasmodium RDTs and was on par with conventional real-time PCR, it could still miss low-density P. malariae infections. This is important because P. malariae infections have lower parasite densities than P. falciparum and can be missed by commonly used PCR assays. However, it is still likely to pick up the majority of P. malariae parasitemia’s detectable by qPCR as well as those contributing to febrile illness [4]. The current assay outperforms pan-Plasmodium RDTs, and a future point-of-care version could fill a key gap in the malaria diagnostic portfolio.

Evidence is limited about P. malariae, including its true prevalence and distribution, and the extent of its propensity to cause chronic carriage and clinical disease. Simpler diagnostic tools that are closer to the point of care could help resolve some of these questions. They may also contribute to efforts to achieve malaria elimination, as all malaria species need to be detected and addressed. The P. malariae-specific RPA-LF assay described here provides a useful laboratory tool for countries seeking to address a key neglected malaria species known for chronic parasitism in low resource settings.

Availability of data and materials

Data is provided in Fig. 3 and as Supplementary Material.

Abbreviations

PCR :

Polymerase chain reaction

qPCR:

Quantitative polymerase chain reaction

RPA :

Recombinase polymerase amplification

RPA-LF :

Recombinase polymerase amplification lateral flow

rRNA :

Ribosomal RNA

RDT :

Rapid diagnostic test

nt:

Nucleotides

NCBI:

National Center for Biotechnology Information

LAMP:

Loop-mediated isothermal amplification (LAMP)

DRC:

Democratic Republic of Congo

CRISPR:

Clustered Regularly Interspaced Short Palindromic Repeats

References

  1. Feachem RGA, Chen I, Akbari O, Bertozzi-Villa A, Bhatt S, Binka F, et al. Malaria eradication within a generation: ambitious, achievable, and necessary. Lancet. 2019;394:1056–112.

    Article  PubMed  Google Scholar 

  2. Yman V, Wandell G, Mutemi DD, Miglar A, Asghar M, Hammar U, et al. Persistent transmission of Plasmodium malariae and Plasmodium ovale species in an area of declining Plasmodium falciparum transmission in eastern Tanzania. PLoS Negl Trop Dis. 2019;13: e0007414.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  3. Sendor R, Banek K, Kashamuka MM, Mvuama N, Bala JA, Nkalani M, et al. Epidemiology of Plasmodium malariae and Plasmodium ovale spp. in Kinshasa Province, Democratic Republic of Congo. Nat Commun. 2023;14:6618.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  4. Sendor R, Mitchell CL, Chacky F, Mohamed A, Mhamilawa LE, Molteni F, et al. Similar prevalence of Plasmodium falciparum and Non-P. falciparum malaria infections among schoolchildren, Tanzania. Emerg Infect Dis. 2023;29:1143–53.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  5. Akala HM, Watson OJ, Mitei KK, Juma DW, Verity R, Ingasia LA, et al. Plasmodium interspecies interactions during a period of increasing prevalence of Plasmodium ovale in symptomatic individuals seeking treatment: an observational study. Lancet Microbe. 2021;2:e141–50.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  6. Sutherland CJ, Oguike MC, Smith V, Betson M, Bousema T, Chiodini PL. Plasmodium ovale sp. and Plasmodium malariae in Africa: difficult items of business on the malaria eradication agenda. Malar J. 2010;9:I10.

    Article  PubMed Central  Google Scholar 

  7. Snounou G, Viriyakosol S, Jarra W, Thaithong S, Brown KN. Identification of the four human malaria parasite species in field samples by the polymerase chain reaction and detection of a high prevalence of mixed infections. Mol Biochem Parasitol. 1993;58:283–92.

    Article  CAS  PubMed  Google Scholar 

  8. Rutledge GG, Böhme U, Sanders M, Reid AJ, Cotton JA, Maiga-Ascofare O, et al. Plasmodium malariae and P. ovale genomes provide insights into malaria parasite evolution. Nature. 2017;542:101–4.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  9. Goman M, Mons B, Scaife J. The complete sequence of a Plasmodium malariae SSUrRNA gene and its comparison to other plasmodial SSUrRNA genes. Mol Biochem Parasitol. 1991;45:281–8.

    Article  CAS  PubMed  Google Scholar 

  10. Parr JB, Kieto E, Phanzu F, Mansiangi P, Mwandagalirwa K, Mvuama N, et al. Analysis of false-negative rapid diagnostic tests for symptomatic malaria in the Democratic Republic of the Congo. Sci Rep. 2021;11:6495.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  11. Assefa A, Mohammed H, Anand A, Abera A, Sime H, Minta AA, et al. Therapeutic efficacies of artemether-lumefantrine and dihydroartemisinin-piperaquine for the treatment of uncomplicated Plasmodium falciparum and chloroquine and dihydroartemisinin-piperaquine for uncomplicated Plasmodium vivax infection in Ethiopia. Malar J. 2022;21:359.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  12. Markwalter CF, Ngasala B, Mowatt T, Basham C, Park Z, Loya M, et al. Direct comparison of standard and ultrasensitive PCR for the detection of Plasmodium falciparum from dried blood spots in Bagamoyo, Tanzania. Am J Trop Med Hyg. 2021;104:1371–4.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  13. Mercereau-Puijalon O, Barale JC, Bischoff E. Three multigene families in Plasmodium parasites: facts and questions. Int J Parasitol. 2002;32:1323–44.

    Article  CAS  PubMed  Google Scholar 

  14. Hofmann NE, Antunes Moniz C, Holzschuh A, Keitel K, Boillat-Blanco N, Kagoro F, et al. Diagnostic performance of conventional and ultrasensitive rapid diagnostic tests for malaria in febrile outpatients in Tanzania. J Infect Dis. 2019;219:1490–8.

    Article  CAS  PubMed  Google Scholar 

  15. Cunningham CH, Hennelly CM, Lin JT, Ubalee R, Boyce RM, Mulogo EM, et al. A novel CRISPR-based malaria diagnostic capable of Plasmodium detection, species differentiation, and drug-resistance genotyping. EBioMedicine. 2021;68: 103415.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  16. Lee RA, Puig HD, Nguyen PQ, Angenent-Mari NM, Donghia NM, McGee JP, et al. Ultrasensitive CRISPR-based diagnostic for field-applicable detection of Plasmodium species in symptomatic and asymptomatic malaria. Proc Natl Acad Sci USA. 2020;117:25722–31.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  17. Lobato IM, O’Sullivan CK. Recombinase polymerase amplification: basics, applications and recent advances. Trends Anal Chem. 2018;98:19–35.

    Article  CAS  Google Scholar 

  18. Xpedite Diagnostics. Recombinase Aided Amplification Kit for detection using lateral flow strips. 2022. https://www.xpedite-dx.com/

Download references

Acknowledgements

The authors thank the study teams involved in sample collection and participants in the parent field studies.

Funding

This project was funded by the National Institutes of Health (R21AI148579 to JBP and JTL). It was partially supported by the Global Fund to Fight AIDS, Tuberculosis and Malaria (DRC and Ethiopia sample collection), and R01AI137395 to JTL (Tanzania sample collection).

Author information

Authors and Affiliations

Authors

Contributions

JBP, JTL, and AA: conceptualized the study. AA, BN, AK, FP, and JBP: data collection, fieldwork, and supervision. AA, KKW, CMH, CHC, and MM: laboratory analyses. AA wrote the first draft. All authors reviewed and approved the final draft.

Corresponding authors

Correspondence to Ashenafi Assefa or Jonathan B. Parr.

Ethics declarations

Competing interests

JBP reports research support from the World Health Organization and Gilead Sciences, non-financial support from Abbott Diagnostics, and consulting from Zymeron Corporation, all outside the scope of this manuscript.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Additional file 1: Table S1.

List of RPA Primers investigated for P. malariae detection in the study.

Additional file 2: Table S2.

Primers and probe set and modifications used in the assay: (1) unlabeled forward primer, (2) reverse primer biotinylated on the 5’ end, and (3) 5’-FAM-labelled probe with an abasic residue and 3’ blocker modification.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Assefa, A., Wamae, K., Hennelly, C.M. et al. Detection of P. malariae using a new rapid isothermal amplification lateral flow assay. Malar J 23, 104 (2024). https://doi.org/10.1186/s12936-024-04928-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12936-024-04928-9

Keywords